The reason why the filling volume of the red wine filling machine is inaccurate or not discharged

Views: 419 Author: Site Editor Publish Time: Origin: Site

9.14

There are some common faults in the production and use of wine filling machines. For example: Why is the filling volume of the wine filling machine inaccurate or not discharging?

  1. Whether the speed throttle valve and the filling interval throttle valve are closed, and whether the throttle valve cannot be closed;

  2. Check whether there is any foreign matter in the quick three-way control valve. If yes, please clean it. Check quick three-way control valve hose and filler head for air. Minimize or exclude air, if present;

  3. Check all sealing rings for damage. If damaged, replace with a new one;

  4. Check whether the fuel nozzle spool is blocked or delayed opening. If clogged, reinstall spool to correct position. If the opening is delayed, the throttle valve of the thin cylinder should be adjusted;

  5. Compress the spring force of the coil spring up and down in the quick-installation three-way control valve to adjust the spring force. If the elastic force is too large, the check valve will not be able to open;

  6. Whether the filling speed is too fast, adjust the filling speed throttle valve to reduce the filling speed;

  7. Check and correct whether all clamps and hose buckles are well sealed;

  8. Check whether the magnetic switch is loose. Please lock it every time you adjust the quantity.


Finding out the cause of the failure of the wine filling machine , proper maintenance can be carried out. If the filling machine is unevenly filled, the end of the joint is tightened, and there is air leakage, which needs to be tightened further. If the machine rotates normally, but no secondary filling liquid is discharged. Check for foreign objects in the valve. If there is, clean it in time; check whether the upper and lower sleeves in the valve are placed incorrectly. The correct method should be that the tips of the two thimbles face down, and they must not be installed in reverse. If the crank does not rotate normally after starting. This situation is easier to handle. When injecting liquid into the syringe, if the upper fixed rod is lower and the inner and outer tubes are pushed hard so that the crank cannot rotate, then loosen the nut, move the upper fixed rod upward to a proper position, and then tighten the nut. If the inner and outer tubes were not cleaned and clamped when the syringe was assembled, remove the syringe and clean it. Observe where the fluid injection system fits into the bearing. If it doesn't work properly, reinstall it.